中文

Sensorless control method for wound-field doubly salient starter/generator with two-section interlaced-rotor structure

Hits:

  • Affiliation of Author(s):自动化学院

  • Journal:IEEE Int. Electric Mach. Drives Conf., IEMDC

  • Abstract:the wound-field doubly salient machine is especially suitable for starter/generator in HVDC power supply system. It has a good prospect of application in aircraft due to its high reliability. To reduce the output voltage ripple, a two-section interlaced-rotor structure is adopted. When only one section is needed to work as a starter, the no-load line Back EMFs of the other section can be applied to sensorless control in medium-high-speed regions. The positive-going zero cross points of the no-load line-to-line voltages are detected to estimate the rotor position. Besides the advantages of simplicity and reliability, this method is not affected by armature reaction and PWM chopping. Further experiments confirm the feasibility of the proposed method. © 2019 IEEE.

  • Translation or Not:no

  • Date of Publication:2019-05-01

  • Co-author:Shi, Chuanzhou,Liu, Weifeng

  • Correspondence Author:whz

  • Date of Publication:2019-05-01

Copyright©2018- Nanjing University of Aeronautics and Astronautics·Informationization Department(Informationization Technology Center) Click:
  MOBILE Version

The Last Update Time:..