Journal:INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Key Words:Conjugated convective heat transfer Hot jet impingement Conical surface Center-satellite orifices
Abstract:A new scheme of center-satellite hot-jet orifices was proposed for improving the conjugated heat transfer performance in the vicinity of a conical concave leading edge. To illustrate the role of this scheme, a typical 6-satellite orifice configuration was designed having the same nominal diameter (d) or ejection area of impinging jets as that of the baseline single-orifice, and a series of experimental tests was performed to determine the hot-jet heating effectiveness under non-dimensional jet-to-leading edge distance (H/d) of 2-4 and nominal jet Reynolds number (Re-j) of 7800-39,400. Four non-dimensional axial distances of satellite-orifice location (H-s/d = 0.15, 0.5, 1.0 and 1.5), three non-dimensional center-orifice diameters (d(c)/d = 0.6875, 0.812 and 0.9375) were taken into consideration. Besides, numerical simulations were also performed to illustrate the effect of center-satellite orifices on the flow and heat transfer features inside the conical concave cavity. The results confirm that the center-satellite scheme has a significant impact on improving the conjugated heat transfer performance in the vicinity of conical wall leading edge due to more intensive jet impingement. In the current research conditions, the satellite-orifice arrangement with a larger non-dimensional axial distance (H-s/d) or a smaller non-dimensional center-orifice diameter (d(c)/d) is suggested to be more favorable for the conjugated heat transfer improvement. However, the center-satellite scheme results in a higher pressure drop related to the baseline single-orifice. It is also noted that the pressure drop of center-satellite scheme is nearly unaffected by the center-orifice diameter and axial distance between center-orifice outlet and satellite-orifice location. (C) 2017 Elsevier Ltd. All rights reserved.
ISSN No.:0017-9310
Translation or Not:no
Date of Publication:2018-01-01
Co-author:Guan, Tao,Lv, Yuan-wei,Shan, Yong,TAN Xiaoming
Correspondence Author:zjz
Pre One:Conjugate heat transfer on leading edge of a conical wall subjected to external cold flow and internal hot jet impingement from chevron nozzle – Part 2: Numerical analysis
Next One:Convective heat transfer on a flat surface induced by a vertically-oriented piezoelectric fan in the presence of cross flow