的个人主页 http://faculty.nuaa.edu.cn/rxy/zh_CN/index.htm
点击次数:
所属单位:自动化学院
发表刊物:THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018)
关键字:harmonics injection bus capacitance CRM boost PFC on-time compensation EN61000-3-2 Class D
摘要:Based on the energy-ripple perspective, this paper discusses the optimum 3rd and 5th order harmonic injection to minimize bus capacitance of CRM boost PFC converters. Within EN61000-3-2 Class D limits, 34% 3rd and 19% 5th order harmonics injection can theoretically achieve the maximum bus capacitance reduction of 36.1% for wide input application (100 similar to 240Vac). However, the conventional on-time control ignores the deviation effect of CRM operation, which introduces the exceeding 3rd and 5th order injected harmonics than EN61000-3-2 Class D limits. In order to eliminate the deviation effect, a novel on-time compensation method is proposed to realize accurate harmonics injection. The experimental results from an 120W prototype show that the maximum bus capacitance reduction of 33% is achieved in practice meeting EN61000-3-2 Class D limits within 100 similar to 240Vac input range.
ISSN号:1048-2334
是否译文:否
发表时间:2018-01-01
合写作者:Guo, Zhehui,吴羽,白雷,张之梁,陈乾宏
通讯作者:任小永