Affiliation of Author(s):自动化学院
Journal:IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY
Key Words:Indirect matrix converter Open-circuit fault Dc-link Clamp circuit
Abstract:Indirect matrix converter (IMC) has attractive advantages such as lack of dc-link electrolytic capacitor, bidirectional power flow and high power density Aiming at faulty condition, this paper presents an analysis work for indirect matrix converter (IMC), which could make contribution to detecting the failure accurately. First, some possible types of open-circuit fault are introduced and the current freewheeling path analysis is presented. Then, combining with space vector modulation (SVM) strategy, the feature of dc-link voltage is analyzed after the occurrence of an open-circuit fault. This analysis result demonstrates that the failure in IMC can be discriminated effectively by measuring dc-link voltage. Experimental results are presented to verify the proposed analytical work. Moreover, a simple design method for clamp circuit is presented in appendix.
ISSN No.:1553-572X
Translation or Not:no
Date of Publication:2017-01-01
Co-author:石宝平
Correspondence Author:Bo Zhou
Date of Publication:2017-01-01