Personal Homepage

Personal Information

MORE+

Degree:Doctoral Degree in Engineering
School/Department:College of Automation Engineering

邢丽冬

+

Education Level:南京航空航天大学

Paper Publications

Characteristics analysis of AC arc fault in time and frequency domain
Date of Publication:2017-01-01 Hits:

Affiliation of Author(s):自动化学院
Journal:2017 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE (PHM-HARBIN)
Key Words:AC arc fault the standard deviation sum of odd harmonic
Abstract:According to the recent research, the analysis of AC arc fault is based on the constant frequency system. The characteristics extracted in the constant frequency system such as the variation rate of current, the ratio of "flat shoulder" and the harmonic change with frequency. Therefore, it cannot apply to the variable frequency system. In this paper, the AC arc experiment platform is built, and the serial and parallel arc faults are simulated under the condition of 115V/360Hz-800Hz. Based on that, the change rule of arc current under different frequency is analyzed. Then, the characteristic of AC arc fault is studied in time domain and frequency domain respectively. The characteristics of AC arc fault are extracted: the standard deviation of the current rms(root mean square), the standard deviation of DC component and the sum of odd harmonic, which can apply to the variable frequency system.
ISSN No.:2166-5656
Translation or Not:no
Date of Publication:2017-01-01
Co-author:Zeng, Ke,Zhang, Yaojia,Wang Li
Correspondence Author:Zeng, Ke,xld
Date of Publication:2017-01-01