Affiliation of Author(s):自动化学院
Journal:IEEE Trans Power Electron
Abstract:The induction machine, offering the merits of robust machine structure, brushless construction, and good voltage regulation capability, is a good choice used as a generator in the dc power system. For the induction generator, the instantaneous torque control (ITC) can achieve stable regulation of the output voltage and excellent dynamic performance of the electromagnetic torque. However, the proportional-integral controller of the voltage loop in the ITC can hardly guarantee the optimal dynamic performance of the output voltage, that is, during the response to the load sudden change, the output voltage exhibits several adjustments, overshoot, and relatively long recovery time. To solve this problem, an instantaneous torque impulse balance control (ITIBC) method is investigated in this paper. In the dynamic process, a group of optimal switch vectors is obtained to achieve the shortest recovery time and the minimum number of adjustments of the output voltage without overshoot. Thus, the optimal dynamic performance of the voltage can be achieved for the induction generator system. Simulation and experimental results verify the correctness and effectiveness of the ITIBC method. © 1986-2012 IEEE.
ISSN No.:0885-8993
Translation or Not:no
Date of Publication:2019-12-01
Co-author:XT10180,Hao, Wenjuan
Correspondence Author:王宇
Date of Publication:2019-12-01
王宇
+
Education Level:南京航空航天大学
Alma Mater:南京航空航天大学
Paper Publications
An Induction Generator System Based on Instantaneous Torque Impulse Balance Control (ITIBC)
Date of Publication:2019-12-01 Hits: