Optimum Harmonics Injection to Minimize Bus Capacitance of CRM Boost PFC Conveters Meeting EN61000-3-2 Class D Limits

Hits:

  • Affiliation of Author(s):自动化学院

  • Journal:THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018)

  • Key Words:harmonics injection bus capacitance CRM boost PFC on-time compensation EN61000-3-2 Class D

  • Abstract:Based on the energy-ripple perspective, this paper discusses the optimum 3rd and 5th order harmonic injection to minimize bus capacitance of CRM boost PFC converters. Within EN61000-3-2 Class D limits, 34% 3rd and 19% 5th order harmonics injection can theoretically achieve the maximum bus capacitance reduction of 36.1% for wide input application (100 similar to 240Vac). However, the conventional on-time control ignores the deviation effect of CRM operation, which introduces the exceeding 3rd and 5th order injected harmonics than EN61000-3-2 Class D limits. In order to eliminate the deviation effect, a novel on-time compensation method is proposed to realize accurate harmonics injection. The experimental results from an 120W prototype show that the maximum bus capacitance reduction of 33% is achieved in practice meeting EN61000-3-2 Class D limits within 100 similar to 240Vac input range.

  • Page Number:2009-2014